28 to 50 kWh · certificate factor 15%
Past this point the battery is rarely the hard part of the job.
Above 28 kWh of usable capacity the certificate factor falls away sharply, and the questions that decide the project stop being about the product — they are about the connection, the supply and the space. 88 approved product lines from 49 brands offer a size in this range.
Quick answer
Home batteries between 28 and 50 kWh of usable capacity attract the federal certificate factor at 15%. 88 product lines from 49 brands hold an approved configuration in this range, covering 1444 registered sizes from 28.3 to 50 kWh usable. The steep drop in the factor at this size is the government signalling that this is no longer the mainstream household case, and most systems here sit behind a business, a farm or a property with several vehicles. Thunderman Electrical and Air Conditioning Services handles the electrical side of battery installation across Greater Melbourne — switchboard work, isolation, backup circuits and grid connection under REC 28523. Free quote, call 0434 254 474.
What this size does to the house
Network approval, three phases and fire separation.
At this scale the installation has more in common with a small commercial job than a domestic one. The certificate factor drops sharply here, which is the government signalling that this band is no longer the mainstream household case — and in practice most systems this size sit behind a business, a farm shed, a large property with a big daytime load, or a home with several cars charging. The constraints stop being about the battery and start being about everything around it: the distributor's approval and any export limit applied to the address, three-phase supply in most cases, fire separation and siting under AS/NZS 5139, and enough switchboard to isolate and protect it properly. Lead times on network approval matter here in a way they never do on a small residential install.
Who it suits
And who it doesn't.
It suits a site with a genuinely large and predictable daytime or evening load — a workshop, a hospitality fitout, a property running pumps or refrigeration, a household with several vehicles. It does not suit an ordinary suburban home hoping for independence from the grid: the capacity is rarely the binding constraint there, the connection agreement and the inverter capacity are, and a system this size can be approved down to something smaller than the brochure implies. If a retailer quotes this band for a normal house without having asked about the supply, that is worth a second opinion.
Approved ranges in this band
Ranges registered this large.
Far fewer lines reach this far, and the ones that do are usually the top of a modular range rather than a distinct product. Capped at 2 lines per brand so one modular range cannot fill the table — 68 lines shown, 20 more in the register. 13 of the 1444 registered sizes in this band have already lapsed and 8 lapse within six months, which is why the expiry column is there.
| Brand | Product line | Usable capacity | Sizes | Listing expires | Status |
|---|---|---|---|---|---|
| Afore | AF-HT Series | 31.33–41.77 kWh | 2 | 2027-12-31 | Listed |
| Alpha ESS | SMILE | 31.2–46.8 kWh | 3 | 2027-12-31 | Listed |
| Alpha ESS | SMILE B5 | 28.73 kWh | 1 | 2027-10-12 | Listed |
| Ambrion | AS3 | 30–50 kWh | 14 | 2027-12-31 | Listed |
| Ambrion | HS3 | 30–50 kWh | 6 | 2027-12-31 | Listed |
| ANKER | Anker SOLIX X1 | 30 kWh | 2 | 2027-12-31 | Listed |
| BLUETTI | B5000 | 33.17–46.44 kWh | 3 | 2027-12-31 | Listed |
| BSLBATT | MatchBox HVS | 31.94–37.27 kWh | 2 | 2027-12-31 | Listed |
| BYD | BATTERY-BOX HVB | 29.69 kWh | 1 | 2027-12-31 | Listed |
| Chelion | iHome | 30–40 kWh | 3 | 2027-05-21 | Listed |
| Deye | AI-W | 30.72 kWh | 1 | 2027-12-31 | Listed |
| Deye | BOS-G-Pro | 30.72–46.08 kWh | 4 | 2027-12-31 | Listed |
| DMEGC | H02 | 30.72–46.08 kWh | 4 | 2027-12-31 | Listed |
| Dyness | Cygni | 29.18–43.77 kWh | 6 | 2027-12-31 | Listed |
| Dyness | STACK100 | 29.18–48.64 kWh | 5 | 2027-12-31 | Listed |
| ESYSUNHOME | 10KWH+H | 30.85–41.14 kWh | 2 | 2027-12-31 | Listed |
| ESYSUNHOME | ESYSUNHOME | 29.18 kWh | 1 | 2026-12-19 | Lapses soon |
| EVOLVE | EVOLVE | 40.44 kWh | 1 | 2026-01-13 | Lapsed |
| Felicity ESS | LUX-X | 29.88–39.84 kWh | 3 | 2027-12-31 | Listed |
| Felicity ESS | LUX-Y | 29.18–48.64 kWh | 5 | 2027-12-31 | Listed |
| Fox ESS | 1K5-BAT-4660 | 32.61–41.93 kWh | 3 | 2027-12-31 | Listed |
| Fox ESS | CQ6 | 29.95–47.92 kWh | 4 | 2027-12-31 | Listed |
| GoodWe | Lynx F G2 | 28.8 kWh | 1 | 2027-12-31 | Listed |
| Growatt | ALP | 30–50 kWh | 5 | 2027-12-31 | Listed |
| Growatt | ALP LV | 30–50 kWh | 5 | 2027-12-31 | Listed |
| HGNESS | HG-C&I-HV | 30.72–46.08 kWh | 4 | 2027-12-31 | Listed |
| Hiconics | HEC2 | 30–40 kWh | 2 | 2027-12-31 | Listed |
| Hiconics | MD-BS | 30 kWh | 1 | 2027-12-31 | Listed |
| HINEN | NA | 32.26–46.08 kWh | 8 | 2027-12-31 | Listed |
| HINEN | Rechargeable Li-ion Battery Pack | 41.04 kWh | 2 | 2027-12-31 | Listed |
| HYXiPOWER | High Voltage Battery | 31.8–42.4 kWh | 2 | 2027-12-31 | Listed |
| JEESENG | JEEDD | 28.56–33.33 kWh | 2 | 2027-12-31 | Listed |
| Kehua Tech | NA | 30–40 kWh | 3 | 2027-05-21 | Listed |
| KSTAR | BlueSpark | 30.1–40.14 kWh | 3 | 2027-12-31 | Listed |
| LIB | LIB BSS01L16 | 32.15–48.23 kWh | 2 | 2027-12-31 | Listed |
| NAHUI | NA | 29.18–38.91 kWh | 3 | 2027-12-31 | Listed |
| NEOVOLT | BW-BAT | 28.8–48 kWh | 3 | not published | Not published |
| NEOVOLT | BW-BAT-9.6P | 36.4–45.5 kWh | 2 | not published | Not published |
| OLiPower | LPBES | 30.72–46.08 kWh | 3 | 2027-12-31 | Listed |
| PotisEdge | ALOE | 28.8 kWh | 2 | 2027-12-31 | Listed |
| PotisEdge | Nora-C06 | 30.72–49.15 kWh | 4 | 2027-12-31 | Listed |
| Pylontech | FH3X | 30.72–35.84 kWh | 8 | 2027-12-31 | Listed |
| Pylontech | Force H3 | 29.8–35.84 kWh | 4 | 2027-12-31 | Listed |
| Pytes | Pi LV1 | 30.72 kWh | 1 | 2027-12-31 | Listed |
| Redback Technologies | RED-P1 | 33.25 kWh | 1 | 2027-12-31 | Listed |
| RENON | Xtreme LV | 28.8 kWh | 1 | 2026-08-17 | Lapsed |
| Risen | Risen Stack1 | 48 kWh | 1 | 2027-12-31 | Listed |
| ROYPOW | RBmax5.5MH series | 30.53 kWh | 1 | 2027-12-31 | Listed |
| SAJ | B2S | 32–44.8 kWh | 4 | 2027-12-31 | Listed |
| Selectronic | SelectCell | 39.78 kWh | 1 | 2027-12-31 | Listed |
| Sigenergy | Sigen Energy Storage System | 28.3–50 kWh | 1177 | 2027-12-31 | Listed |
| Sigenergy | SigenStack Energy Storage System | 46.8 kWh | 2 | 2027-12-31 | Listed |
| SkyVolt | SkyVolt S | 28.74–33.54 kWh | 2 | 2027-12-31 | Listed |
| SolaX | T-BAT-SYS-HV-S3.6 | 29.7–43.1 kWh | 5 | 2026-10-23 | Lapses soon |
| SolaX | TSYS-HS51 | 30.7–46 kWh | 4 | 2027-12-31 | Listed |
| Solplanet | AP-H | 30.72–46.08 kWh | 4 | 2027-12-31 | Listed |
| SUMRAY | SR-LV10G | 36.99–46.24 kWh | 2 | 2027-12-31 | Listed |
| SUMRAY | SR-LV14G | 41.76 kWh | 1 | 2027-12-31 | Listed |
| Sungrow | SBH | 30–40 kWh | 3 | not published | Not published |
| Sungrow | ST050-250CF | 49.9 kWh | 1 | 2027-12-31 | Listed |
| SUNSYNK | High Voltage | 32.25–46.08 kWh | 4 | not published | Not published |
| Swatten | SieB-HP-F | 30.72–46.08 kWh | 4 | 2027-12-31 | Listed |
| Tesla | Powerwall 3 AC with Backup Gateway 2 | 40.5 kWh | 1 | 2027-12-31 | Listed |
| Tesla | Powerwall 3 and Expansions with Backup Gateway 2 | 40.5 kWh | 3 | 2027-12-31 | Listed |
| WECO | 5K0 PRO | 30–45 kWh | 4 | 2027-12-31 | Listed |
| ZRGP | Power Base LV-Mate_100 | 29.8–39.73 kWh | 3 | not published | Not published |
| ZYC Energy | SIMPO HV | 28.8 kWh | 1 | 2027-12-31 | Listed |
| ZYC Energy | SIMPO HV Pro | 32.2–48.3 kWh | 3 | 2027-12-31 | Listed |
A product line is one family, andsizes is how many separate configurations of it are registered — modular systems are registered once per stack size, which is why some lines show dozens. Usable capacity is the figure the certificate tiers are calculated on, and it is always lower than the nominal capacity printed on the box.Listing expires is the date the Clean Energy Council approval lapses; after it, that configuration can no longer earn certificates. All of it is as published in the Clean Energy Council approved battery list, so you can look up any line yourself.
Wrong size?
Look either side.
Capacities and expiry dates from the Clean Energy Council approved battery list, published by the Clean Energy Regulator, as published on 2026-08-20. Look any line up yourself atthe register.
28 to 50 kWh home batteries — common questions
Is there any point going above 50 kWh?
There can be, but not for the certificates. Certificates can only be claimed on the first 50 kWh of usable capacity, so anything beyond that has to justify itself on its own merits — a genuine load, a resilience requirement, an off-grid or edge-of-grid site. Batteries larger than 50 kWh are registered and installed in Australia and there is nothing wrong with them; they are simply outside what the household program was designed to support. If someone is proposing one, the question to ask is what specific load or outage requirement it is answering, and whether the connection at that address will actually permit it.
How many batteries are approved in the 28 to 50 kWh range?
88 product lines from 49 brands offer at least one approved configuration between 28 and 50 kWh, which works out to 1444 separate registered sizes. 1 of those lines cover this range only — they are built for it rather than reaching into it from above or below. Those are configurations on the Clean Energy Council approved battery list rather than products on a shelf, so a retailer's catalogue will look different in both directions.
What does the certificate factor of 15% mean for this size?
It is the weighting applied to this slice of usable capacity when small-scale technology certificates are calculated — not a price, and not a figure Thunderman sets. The Clean Energy Regulator applies the full factor to the first band of usable capacity and steps it down for the bands above, so a larger battery does not attract proportionally more support. Certificates are also determined by the date the system is installed rather than the date the contract is signed, and nothing can be claimed beyond the first 50 kWh of usable capacity. What that comes to in money depends on the certificate market on the day and on your installer's arrangements, which is why the figure belongs in a written quote rather than on a web page.
Is nominal capacity or usable capacity the one that counts?
Both, for different things, and quotes mix them up constantly. Nominal capacity decides whether a battery is eligible at all — it has to fall between 5 and 100 kWh. Usable capacity is what the tiers are calculated on and what you actually get to use, and it is always the smaller number. In this range the approved configurations run from 28.3 to 50 kWh usable. If a quote gives you one figure and not the other, ask for both before comparing it against anything.
The battery is the easy half. The switchboard decides the job.
Yiannis will look at what the board can actually carry, which circuits are worth keeping alive in an outage, and what the distributor will approve at your address — then quote the whole job. Free quote, REC 28523.