Skip to content

5 kW class

5 kW split systems, compared on the figures that matter.

A 5 kW unit typically suits a main living area — roughly 23 to 46 square metres depending on which way it faces, how well it is insulated and how many people use it. 72 models in this class are registered with the Australian Government, from ten of the ten brands compared here.

Quick answer

A 5 kW split system air conditioner suits a room of roughly 23 to 46 square metres — typically a main living area — with the exact figure depending on orientation, insulation, ceiling height and occupancy. Among the ten brands compared here, 72 distinct 5 kW-class models are registered with the Australian Government's GEMS database, from ten of them: Carrier, Daikin, Fujitsu, Gree, Hisense, Kaden, Mitsubishi Electric, Mitsubishi Heavy Industries, TCL, Teco. In this class the highest cooling efficiency figure is AEER 4.41 and the highest heating efficiency figure is ACOP 4.9, and the lowest declared indoor noise level is 49.38 dB. Thunderman supplies and installs Kaden, Hisense, Teco, Gree, Mitsubishi Heavy Industries, TCL, Fujitsu and Mitsubishi Electric units in this class across Melbourne's north and north-west — electrical work under REC 28523, refrigerant work under ARCtick.

What this size means on the job

The part a showroom won't tell you.

5 kW is the main living area size in most Melbourne homes, and it is where the electrical side starts to matter properly. A unit this size will usually want its own dedicated circuit rather than sharing with power points, and on an older board that means checking there is a spare way and that the main switch and supply can carry it. This is the class where a quote that ignores the switchboard is a quote that will change later. It is also where the heating figure earns its keep — Melbourne uses a reverse-cycle unit for heat far more of the year than for cooling, so the ACOP number is doing more work than the cooling star rating a showroom will point at.

Quietest in this class

Ranked by declared indoor noise.

In this class the declared indoor noise levels run from 49.38 dB to 64.1 dB — a spread of 15 dB between the quietest and the loudest, which is a difference you would hear plainly in the same room. Capped at three models per brand so one range cannot fill the table.

Model Cooling Heating Indoor noise AEER ACOP Stars Registration
TCL TAC-18CHSD/TPH11IT 5.2 kW 5.2 kW 49.38 dB 3.67 4.27 3.5 / 2.5 AAC7663
Teco TWS-TSO52H3DVJT 5.2 kW 5.2 kW 51.8 dB 3.42 4.27 3 / 2.5 AAC7277
Mitsubishi Electric MSZ-EF50VGDB +6 variants 5 kW 5.8 kW 55.2 dB 3.22 3.71 3 / 2.5 AAC8153
Mitsubishi Electric MSZ-LN50VG3B +2 variants 5 kW 6 kW 56.5 dB 3.61 4.04 3.5 / 2.5 AAC7439
Mitsubishi Electric MSZ-LN50VG3B +5 variants 5 kW 6 kW 56.8 dB 3.61 4.07 3 / 2.5 AAC7440
TCL TFM2-18CHD/DVO 5.2 kW 5.2 kW 56.92 dB 3.76 4.44 3.5 / 3 AAC8810
Kaden KSI18 5 kW 5.2 kW 57 dB 3.84 3.84 4 / 2.5 AAC10147
Carrier 42QAG050N8 5 kW 5.35 kW 57.83 dB 3.67 3.66 4 / 2.5 AAC7707

Cooling and heating are rated capacity. AEER and ACOP are the annual efficiency figures for cooling and heating — higher is cheaper to run. Stars are shown as cooling / heating for a mixed climate zone, which is the one Melbourne sits in. Indoor noise is the manufacturer's declared sound level for the indoor unit. Every figure is as registered with the Australian Government's GEMS register, and the registration number is there so you can look it up yourself.

Cheapest to run — cooling

Ranked by AEER.

Cooling efficiency in this class runs from AEER 3.12 to 4.41 — the most efficient unit here delivers about 41% more cooling per unit of power than the weakest. That gap is what you are choosing between, and it does not show up on the star sticker, because stars are banded.

Model Cooling Heating Indoor noise AEER ACOP Stars Registration
Daikin FTXM50AVMA 5 kW 6 kW 61 dB 4.41 4.9 5 / 3.5 AAC10039
Daikin FTXM50WVMA 5 kW 6 kW 61 dB 4.41 4.86 5 / 3.5 AAC10191
Daikin FTXM50W2VMA 5 kW 6 kW 61 dB 4.4 4.85 4.5 / 3.5 AAC6735
Fujitsu ASTG18KMTC 5 kW 6 kW 61 dB 4.3 4.68 4.5 / 2.5 AAC8712
Fujitsu ASTH18KMTD 5 kW 6 kW 61 dB 4.3 4.68 4.5 / 3 AAC7569
Gree GWH18QEXF-K6DNA +2 variants 5.2 kW 5.6 kW 61 dB 4.3 4.52 4.5 / 3 AAC6539
Hisense HAW18KR +2 variants 5.1 kW 5.8 kW 62.3 dB 4.16 4.07 4.5 / 2.5 AAC9279
Mitsubishi Electric MSZ-GS50VFD +1 variant 5 kW 5.5 kW 60.2 dB 4.11 4.24 3.5 / 2.5 AAC9086

Best for a Melbourne winter

Ranked by ACOP — the heating figure.

Heating efficiency here runs from ACOP 3.24 to 4.9, a spread of about 51%. Because Melbourne runs a reverse-cycle system for warmth far more of the year than for cooling, that spread costs more over time than the cooling one does — and this ranking is rarely the same as the one above it.

Model Cooling Heating Indoor noise AEER ACOP Stars Registration
Daikin FTXM50AVMA 5 kW 6 kW 61 dB 4.41 4.9 5 / 3.5 AAC10039
Daikin FTXM50WVMA 5 kW 6 kW 61 dB 4.41 4.86 5 / 3.5 AAC10191
Daikin FTXM50W2VMA 5 kW 6 kW 61 dB 4.4 4.85 4.5 / 3.5 AAC6735
Fujitsu ASTG18KMTC 5 kW 6 kW 61 dB 4.3 4.68 4.5 / 2.5 AAC8712
Fujitsu ASTH18KMTD 5 kW 6 kW 61 dB 4.3 4.68 4.5 / 3 AAC7569
Gree GWH18QEXF-K6DNA +2 variants 5.2 kW 5.6 kW 61 dB 4.3 4.52 4.5 / 3 AAC6539
TCL TFM2-18CHD/DVO 5.2 kW 5.2 kW 56.92 dB 3.76 4.44 3.5 / 3 AAC8810
Mitsubishi Heavy Industries SRK50ZSXA-W 5 kW 6 kW 59 dB 4 4.38 3.5 / 3 AAC8725

Not sure this is the right size?

Look either side.

All figures from the GEMS registration database (Australian Government). Every model above carries its registration number so you can check it at the register.

5 kW air conditioners — common questions

Does a 5 kW split system need its own circuit?

Generally yes. A unit at this capacity is normally wired to a dedicated circuit rather than run off an existing power-point circuit, which means the switchboard needs a spare way and enough capacity to take it. On a modern board that is routine. On an older board with ceramic fuses or no RCD protection it becomes a switchboard job first, which is worth establishing before the unit is ordered rather than on the day.

How many 5 kW models are registered across the ten brands compared here?

Among the ten brands compared here, 72 distinct models in this capacity class are currently registered with the Australian Government's GEMS database, from ten of them: Carrier, Daikin, Fujitsu, Gree, Hisense, Kaden, Mitsubishi Electric, Mitsubishi Heavy Industries, TCL, Teco. That count is registrations rather than shelf listings — a single registration often covers several colourways of the same unit, which is why a retailer's catalogue looks larger.

What is the quietest 5 kW air conditioner?

The lowest declared indoor sound level in this class is 49.38 dB. Noise figures are declared by the manufacturer at a stated fan speed, so they compare like with like between models but will not match what you measure in a room — where the mounting position, the wall and the furnishings all change what you hear. A unit that is quiet on paper and badly positioned will still be the loudest thing in a bedroom.

Does a 5 kW unit heat as well as it cools?

Not necessarily, and in Melbourne that is the question worth asking. In this class the highest cooling efficiency figure (AEER) is 4.41 and the highest heating figure (ACOP) is 4.9, and they usually belong to different models. Because a reverse-cycle system here runs for warmth far more of the year than for cooling, the heating figure generally deserves more weight than the cooling star rating a showroom will point at.

Right size, wrong switchboard is still the wrong job.

Yiannis will confirm the capacity against the actual room, check the board can carry it, and quote the whole job rather than the easy half. Free quote, ARCtick certified, REC 28523.

WhatsApp