8 kW split systems, compared on the figures that matter.

A 8 kW unit typically suits a large open-plan area — roughly 37 to 73 square metres depending on which way it faces, how well it is insulated and how many people use it. 32 models in this class are registered for sale in Australia across 8 brands.

Quick answer

A 8 kW split system air conditioner suits a room of roughly 37 to 73 square metres — typically a large open-plan area — with the exact figure depending on orientation, insulation, ceiling height and occupancy. 32 distinct 8 kW-class models are registered with the Australian Government's GEMS database across 8 brands: Carrier, Daikin, Fujitsu, Hisense, Mitsubishi Electric, Mitsubishi Heavy Industries, TCL, Teco. In this class the best cooling efficiency figure is AEER 3.66 and the best heating efficiency figure is ACOP 4.42, and the lowest declared indoor noise level is 52 dB. Thunderman Electrical and Air Conditioning Services supplies and installs units in this class across Greater Melbourne under ARCtick certification, with electrical work by REC 28523.

What this size means on the job

The part a showroom won't tell you.

At 8 kW the conversation shifts from comfort to capacity. A unit this size is a serious electrical load, and whether a house can take it depends on the switchboard and the incoming supply rather than on the unit itself. Older homes in the northern suburbs frequently have a board that was adequate for a house with one heater and no air conditioning, and adding a load of this size to it is a switchboard upgrade with an aircon attached. That is not a reason to size down — an undersized unit running permanently at full tilt is worse on every measure — but it is a reason to have the electrical side assessed before committing.

Quietest in this class

Ranked by declared indoor noise.

In this class the declared indoor noise levels run from 52 dB to 67.9 dB — a spread of 16 dB between the quietest and the loudest, which is a difference you would hear plainly in the same room.Capped at three models per brand so one range cannot fill the table.

ModelCoolingHeatingIndoor noiseAEERACOPStarsRegistration
TCLTPH11IT8.2 kW8.5 kW52 dB3.543.673 / 2.5AAC7665
TecoTWS-TSO88H3DVJT8.8 kW8.8 kW53.9 dB3.493.883 / 2.5AAC7373
TecoTWS-TSO88H3DVKT8.8 kW8.8 kW53.9 dB3.493.883 / 2.5AAC8920
TCLDVO7.9 kW7.9 kW56.92 dB3.394.423 / 3AAC8812
Mitsubishi Heavy IndustriesDXK_80+2 variants8 kW9 kW58 dB3.593.733 / 2.5AAC8718
Mitsubishi Heavy IndustriesDXK28ZRA-WF1+1 variant8 kW9 kW58 dB3.583.733.5 / 2.5AAC8227
Mitsubishi Heavy IndustriesDXK28ZRA-WF+1 variant8 kW9 kW58 dB3.583.733 / 2.5AAC7758
Mitsubishi ElectricMSZ-AP80VGD+3 variants7.8 kW9 kW61.5 dB3.33.523 / 2.5AAC6352

Cooling and heating are rated capacity. AEER andACOP are the annual efficiency figures for cooling and heating — higher is cheaper to run. Stars are shown as cooling / heating for a mixed climate zone, which is the one Melbourne sits in. Indoor noise is the manufacturer's declared sound level for the indoor unit. Every figure is as registered with the Australian Government's GEMS register, and the registration number is there so you can look it up yourself.

Cheapest to run — cooling

Ranked by AEER.

Cooling efficiency in this class runs from AEER 3.22 to 3.66 — the best unit here delivers about 14% more cooling per unit of power than the weakest. That gap is what you are choosing between, and it does not show up on the star sticker, because stars are banded.

ModelCoolingHeatingIndoor noiseAEERACOPStarsRegistration
DaikinFTXV80WVMA8 kW9 kW67 dB3.663.253 / 2AAC6830
DaikinFTXM85WVMA8.5 kW9 kW65 dB3.593.363 / 2AAC6829
Mitsubishi Heavy IndustriesDXK_80+2 variants8 kW9 kW58 dB3.593.733 / 2.5AAC8718
Mitsubishi Heavy IndustriesDXK28ZRA-WF1+1 variant8 kW9 kW58 dB3.583.733.5 / 2.5AAC8227
Mitsubishi Heavy IndustriesDXK28ZRA-WF+1 variant8 kW9 kW58 dB3.583.733 / 2.5AAC7758
TCLTPH11IT8.2 kW8.5 kW52 dB3.543.673 / 2.5AAC7665
TecoTWS-TSO88H3DVJT8.8 kW8.8 kW53.9 dB3.493.883 / 2.5AAC7373
TecoTWS-TSO88H3DVKT8.8 kW8.8 kW53.9 dB3.493.883 / 2.5AAC8920

Best for a Melbourne winter

Ranked by ACOP — the heating figure.

Heating efficiency here runs from ACOP 3.24 to 4.42, a spread of about 36%. Because Melbourne runs a reverse-cycle system for warmth far more of the year than for cooling, that spread costs more over time than the cooling one does — and this ranking is rarely the same as the one above it.

ModelCoolingHeatingIndoor noiseAEERACOPStarsRegistration
TCLDVO7.9 kW7.9 kW56.92 dB3.394.423 / 3AAC8812
TecoTWS-TSO88H3DVJT8.8 kW8.8 kW53.9 dB3.493.883 / 2.5AAC7373
TecoTWS-TSO88H3DVKT8.8 kW8.8 kW53.9 dB3.493.883 / 2.5AAC8920
FujitsuASTG30KMTC8.5 kW9 kW64 dB3.433.822.5 / 2AAC8709
FujitsuASTH30KMTD8.5 kW9 kW65 dB3.413.763.5 / 3AAC7647
FujitsuASTH30KNTA8.5 kW9 kW65 dB3.413.763.5 / 3AAC7648
DaikinFTXF80AVMA7.8 kW9 kW66 dB3.263.733 / 2AAC10286
Mitsubishi Heavy IndustriesDXK_80+2 variants8 kW9 kW58 dB3.593.733 / 2.5AAC8718

Not sure this is the right size?

Look either side.

All figures from the GEMS registration database (Australian Government). Every model above carries its registration number so you can check it atthe register.

8 kW air conditioners — common questions

Can my house handle an 8 kW air conditioner?

That depends on the switchboard and the supply, not on the unit. A unit at this capacity needs a dedicated circuit and enough spare capacity at the board to carry it. Many older Melbourne homes have a board sized for a household that had neither air conditioning nor an induction cooktop, and adding this load means upgrading the board first. A licensed electrician can tell you which situation you are in by looking at the board.

How many 8 kW models are sold in Australia?

32 distinct models in this capacity class are currently registered with the Australian Government's GEMS database, across 8 brands: Carrier, Daikin, Fujitsu, Hisense, Mitsubishi Electric, Mitsubishi Heavy Industries, TCL, Teco. That count is registrations rather than shelf listings — a single registration often covers several colourways of the same unit, which is why a retailer's catalogue looks larger.

What is the quietest 8 kW air conditioner?

The lowest declared indoor sound level in this class is 52 dB. Noise figures are declared by the manufacturer at a stated fan speed, so they compare like with like between models but will not match what you measure in a room — where the mounting position, the wall and the furnishings all change what you hear. A unit that is quiet on paper and badly positioned will still be the loudest thing in a bedroom.

Does a 8 kW unit heat as well as it cools?

Not necessarily, and in Melbourne that is the question worth asking. In this class the best cooling efficiency figure (AEER) is 3.66 and the best heating figure (ACOP) is 4.42, and they usually belong to different models. Because a reverse-cycle system here runs for warmth far more of the year than for cooling, the heating figure generally deserves more weight than the cooling star rating a showroom will point at.

Right size, wrong switchboard is still the wrong job.

Yiannis will confirm the capacity against the actual room, check the board can carry it, and quote the whole job rather than the easy half. Free quote, ARCtick certified, REC 28523.