What is on an electrical safety check report, and why it matters

The electrical safety check report — not the visit — is what protects you later. Here's what the record must legally contain, how it differs from a CoES, and what a thorough one adds.

An open residential switchboard being tested during a periodic electrical safety check

Quick answer

When a licensed electrician does the two-yearly rental electrical safety check, the thing that protects you afterwards isn’t the visit — it’s the report. The visit happens once and is gone; the record is what you show an owner, an incoming agent, an insurer, or the regulator, sometimes years later. Victorian law sets out exactly what that record must contain, and it’s worth knowing — because a report that meets the legal minimum and a report that actually protects you are not always the same document.

What the record must legally contain

The Residential Tenancies Regulations 2021 are specific about the record. It must include:

  • the name of the licensed or registered electrician who did the check;
  • their licence or registration number;
  • the date the check was conducted;
  • the results, including any repairs that were required and the actions taken to address them; and
  • a report prepared to section 2 of AS/NZS 3019, the periodic-verification standard.

That last point is the one most people miss. The check itself is carried out to section 4 of AS/NZS 3019 — “Electrical installations: Periodic verification” — and the written report is the section 2 output of that same standard. It’s a defined piece of work with a defined format, not a note scribbled on a job docket.

The regulation describes the scope broadly: a check of all electrical installations, fixtures and fittings. In practice — and this is Energy Safe Victoria’s guidance and the substance of AS/NZS 3019, rather than the exact words of the regulation — that means the switchboard, the wiring, the fittings, the power points, and testing that the safety switches actually trip. A report that names what was inspected and tested is doing its job; one that just says “passed” is not.

Why it isn’t a Certificate of Electrical Safety

This trips up a lot of people, so it’s worth being plain about it. The periodic check report is not a Certificate of Electrical Safety.

A CoES is a statutory certificate issued when electrical work is carried out — new wiring, a switchboard upgrade, or fixing a fault. The two-yearly check is an inspection of the existing installation, and its output is the AS/NZS 3019 report. Energy Safe Victoria says so directly: a CoES is not the correct form for the periodic safety check.

Where the two meet is remediation. If the check finds a defect and an electrician then rectifies it, that repair is electrical work — so it gets its own CoES, on top of the check report. So a check that turns something up can leave you with two documents: the periodic report saying what was found, and the CoES saying the fix was done and certified. An electrician who hands you only one of those, when the job needed both, has left a gap in your paperwork.

The honest difference between “compliant” and “useful”

The legal minimum is a floor. A report that lists the five required items is compliant — and can still leave you exposed, because it doesn’t tell the story.

The difference is detail. A report worth keeping records what was actually inspected and tested, not just the verdict. It notes faults found and, crucially, whether they were rectified or left as a recommendation — because an outstanding recommendation is something you have to disclose to the next applicant, and you can’t disclose what wasn’t written down. It includes photographs of the switchboard and any defect, so a dispute two years later isn’t one person’s memory against another’s. And it’s honest about limits: if a circuit couldn’t be fully tested because a room was inaccessible, a good report says so rather than implying a clean bill it didn’t earn.

None of that is required by the regulation. All of it is the difference between paperwork that satisfies a rule and paperwork that protects the person holding it.

Who ends up relying on it

The report matters because of who reads it later, and the one question each of them is really asking: what did you know, when, and what did you do about it?

  • The owner wants evidence their property was looked after — especially if a managing agent changes.
  • The incoming agent, taking over a rent roll around Reservoir or Coburg, wants to inherit a clear history instead of starting every property from zero.
  • An insurer, after an electrical fault or fire, can ask for proof the installation was checked and maintained. A dated report by a named, licensed electrician is exactly that.
  • The regulator or a tribunal, if compliance is ever questioned, wants the record — and “we had it done, but there’s no report” is a weak place to stand.

A good report answers all four in one document. A thin one answers none of them well.

Keeping it straight, in practice

Two practical points managers get wrong. First, retention: Victorian law doesn’t set a number of years — the record is simply kept until the next check replaces it, so you always hold the most recent one. Second, the renter’s rights: you provide the date of the check in writing on request, and a full copy within 7 days of a written request; an applicant must be told the date and any outstanding recommendations before they sign. Keeping the report filed against the address, rather than in an inbox, is what makes all of that a two-minute job instead of a scramble.

What to do next

If you’re arranging checks across a portfolio, ask the electrician one question before they start: what does your report include? The answer tells you whether you’re buying a compliant tick or a document you can actually rely on. For the plain-language version of the check itself, the rental electrical safety checklist sets it out.

Thunderman’s electrical safety checks come back with the AS/NZS 3019 report, photographs, a clear note of anything found and what was done about it, and the certificate for any remedial work — filed so you can produce it the day you need it. Managing a portfolio? Yiannis can review the whole lot. Call 0434 254 474 or send a message — REC 28523, across Greater Melbourne.

Sources

Common questions

What must an electrical safety check record legally contain in Victoria?

Under the Residential Tenancies Regulations 2021, the record must include the name of the licensed or registered electrician who did the check, their licence or registration number, the date it was conducted, the results — including any repairs required and the actions taken — and a report prepared in accordance with section 2 of AS/NZS 3019. That's the legal minimum; a good report adds the detail that makes it useful.

Is the check report the same as a Certificate of Electrical Safety?

No, and it matters. The two-yearly check produces a periodic-verification report under AS/NZS 3019. A Certificate of Electrical Safety (CoES) is a separate document, issued when actual electrical installation or repair work is carried out — for example, fixing a fault the check found. A CoES is not the correct form for the periodic check itself.

How long do I have to keep the electrical safety check record?

Victorian law doesn't set a number of years. The regulation says the record is kept until a record of the next check is created — so you always hold the most recent one. If you've seen a 'five-year' rule quoted, that's the UK standard, not Victoria's.

Does the renter get a copy of the report?

The renter is entitled to the date of the most recent check in writing on request, and to a full copy of the check within 7 days of a written request. Separately, an applicant must be told the date of the most recent check and any outstanding recommendations before they sign. The 7 days runs from the request, not from the day the check was done.

What standard does the check follow?

The check is carried out to section 4 of AS/NZS 3019, 'Electrical installations — Periodic verification', and the record includes a report to section 2 of the same standard. That's the standard for verifying an existing installation — different from AS/NZS 3000, the wiring rules that govern new installation work.

Yiannis Knodarites, licensed Melbourne electrician — Thunderman Electrical and Air Conditioning Services

The owner does your job

You'll get Yiannis — not a subcontractor.

Book Thunderman and the licensed electrician who quotes your job is the one who does it — and stands behind it afterwards. REC 28523, ARCtick certified, fully insured, rated 4.9★ across 53 Google reviews.

More from the Journal

Got a follow-up question? Just call.

Free quotes across Greater Melbourne — Yiannis answers personally.

WhatsApp