Skip to content

18 registered models

Kaden split systems, as the register lists them.

2 kW to 9 kW, across 6 of the eight capacity classes. Sold as 18 variants once colourways and trim levels are counted, which is why a retailer's catalogue looks bigger than the register does.

Quick answer

18 distinct Kaden wall-mounted single-phase reverse-cycle air conditioners are registered with the Australian Government's GEMS database, ranging from 2 kW to 9 kW and covering 6 of the eight capacity classes the Australian market advertises. Across the range the highest annual cooling efficiency figure is AEER 4.63 and the highest heating efficiency figure is ACOP 4.87, with the lowest declared indoor noise level at 52.94 dB. Thunderman Electrical and Air Conditioning Services Pty Ltd installs split systems across Greater Melbourne under ARCtick certification with electrical work by REC 28523, and advises on selection using the register rather than manufacturer marketing.

What the register says about this range

The honest summary.

The register shows Kaden short of common sizes: there is no 4.5 kW model and no 6 kW model, so the 18 registered models between 2 kW and 9 kW cover six of the eight capacity classes. Its top cooling efficiency, AEER 4.63, is the lowest of the ten brands compared; its top heating efficiency, ACOP 4.87, ranks sixth of the ten. The quietest Kaden unit declares 52.94 dB indoors. Each registration is a single model, with no colourway duplicates.

Who this range suits

And who it doesn't.

This is not the range to pick for a bedroom where noise decides it. The quietest Kaden on the register declares 52.94 dB indoors, against 47 dB for the quietest of the ten brands compared, and from 5 kW upwards nothing is declared below 57 dB. Where it holds up is a small room that is heated more than it is cooled: the KSI06 (AAC10143) and KSI-2.5 (AAC9152) reach ACOP 4.87, above their own cooling figures of AEER 4.63 and 4.61. At 5 kW and above the highest heating figure falls to ACOP 4.21.

Worth knowing before you settle on the brand: there is no Kaden model registered in the 4.5 kW or 6 kW classes. If that is the size your room needs, the choice is another brand or the neighbouring capacity — and which of those is right depends on the room rather than on preference.

Supply and installation

Thunderman and Kaden

Thunderman supplies and installs Kaden split systems across Melbourne's north and north-west — electrical work under REC 28523, refrigerant work under ARCtick. If you're weighing Kaden against another brand here, tell us the room and we'll put the figures side by side. Free quote, no obligation.

Get a free quote

Quietest in this range

Ranked by declared indoor noise.

Model Cooling Heating Indoor noise AEER ACOP Stars Registration
Kaden KSI-2.0 2.05 kW 2.37 kW 52.94 dB 4.63 4.63 4.5 / 3 AAC9134
Kaden KSI06 2 kW 2.25 kW 53 dB 4.63 4.87 5 / 3 AAC10143
Kaden KSI09 2.6 kW 2.7 kW 55 dB 4.39 4.48 5 / 3 AAC10149
Kaden KSI12 3.55 kW 4 kW 56 dB 4.31 4.33 4.5 / 3 AAC10140
Kaden KSI-2.5 2.5 kW 2.795 kW 56.65 dB 4.61 4.87 5 / 3.5 AAC9152
Kaden KSI18 5 kW 5.2 kW 57 dB 3.84 3.84 4 / 2.5 AAC10147
Kaden KS09 2.6 kW 2.8 kW 58 dB 4.31 4.29 4.5 / 2.5 AAC6827
Kaden KS12 3.5 kW 3.8 kW 58 dB 4.01 4.35 4 / 3 AAC6839

Cooling and heating are rated capacity. AEER and ACOP are the annual efficiency figures for cooling and heating — higher is cheaper to run. Stars are shown as cooling / heating for a mixed climate zone, which is the one Melbourne sits in. Indoor noise is the manufacturer's declared sound level for the indoor unit. Every figure is as registered with the Australian Government's GEMS register, and the registration number is there so you can look it up yourself.

Most efficient — cooling

Ranked by AEER.

Model Cooling Heating Indoor noise AEER ACOP Stars Registration
Kaden KSI06 2 kW 2.25 kW 53 dB 4.63 4.87 5 / 3 AAC10143
Kaden KSI-2.0 2.05 kW 2.37 kW 52.94 dB 4.63 4.63 4.5 / 3 AAC9134
Kaden KSI-2.5 2.5 kW 2.795 kW 56.65 dB 4.61 4.87 5 / 3.5 AAC9152
Kaden KSI09 2.6 kW 2.7 kW 55 dB 4.39 4.48 5 / 3 AAC10149
Kaden KS09 2.6 kW 2.8 kW 58 dB 4.31 4.29 4.5 / 2.5 AAC6827
Kaden KSI12 3.55 kW 4 kW 56 dB 4.31 4.33 4.5 / 3 AAC10140
Kaden KSI-3.5 3.5 kW 4 kW 58.99 dB 4.11 4.29 4.5 / 3 AAC9137
Kaden KS12 3.5 kW 3.8 kW 58 dB 4.01 4.35 4 / 3 AAC6839

Most efficient — heating

Ranked by ACOP, the figure Melbourne runs on.

Model Cooling Heating Indoor noise AEER ACOP Stars Registration
Kaden KSI06 2 kW 2.25 kW 53 dB 4.63 4.87 5 / 3 AAC10143
Kaden KSI-2.5 2.5 kW 2.795 kW 56.65 dB 4.61 4.87 5 / 3.5 AAC9152
Kaden KSI-2.0 2.05 kW 2.37 kW 52.94 dB 4.63 4.63 4.5 / 3 AAC9134
Kaden KSI09 2.6 kW 2.7 kW 55 dB 4.39 4.48 5 / 3 AAC10149
Kaden KS12 3.5 kW 3.8 kW 58 dB 4.01 4.35 4 / 3 AAC6839
Kaden KSI12 3.55 kW 4 kW 56 dB 4.31 4.33 4.5 / 3 AAC10140
Kaden KS09 2.6 kW 2.8 kW 58 dB 4.31 4.29 4.5 / 2.5 AAC6827
Kaden KSI-3.5 3.5 kW 4 kW 58.99 dB 4.11 4.29 4.5 / 3 AAC9137

Sizes in this range

Where Kaden competes.

Compare with another brand

All figures from the GEMS registration database (Australian Government), covering 459 registered models across 10 brands. Every model above carries its registration number so you can check it at the register.

Kaden air conditioners — common questions

How many Kaden split systems are sold in Australia?

18 distinct Kaden wall-mounted single-phase reverse-cycle models are registered with the Australian Government's GEMS database, sold as 18 variants once colourways and trim levels are counted separately. They span 2 kW to 9 kW and cover 6 of the eight capacity classes the Australian market advertises — the gaps are 4.5 kW and 6 kW.

Is Kaden good for heating in Melbourne?

The highest annual heating efficiency figure across the Kaden range on the register is ACOP 4.87, against 4.63 for cooling (AEER). In Melbourne the heating figure carries more weight, because a reverse-cycle system here runs for warmth far more of the year than for cooling. Those are the range's best figures, not typical ones — individual models vary, which is why the tables above list them separately rather than giving the brand a single score.

What is the quietest Kaden air conditioner?

The lowest declared indoor sound level in the Kaden range is 52.94 dB. Declared figures are measured by the manufacturer at a stated fan speed, so they compare fairly against other brands' declared figures but will not match what you measure in a room — mounting position and the surfaces around the unit change that considerably.

Does Thunderman install Kaden air conditioners?

Yes. Thunderman supplies and installs Kaden split systems across Melbourne's north and north-west. Yiannis is ARCtick certified, which is what handling refrigerant legally requires, and electrical work is carried out under REC 28523. Yiannis quotes the whole job free of charge.

Brand chosen. Now the part that decides whether it works.

Sizing against the actual room, whether the switchboard can carry it, and where the head should go. Yiannis quotes the whole job free of charge — ARCtick certified, REC 28523.

WhatsApp